RST series X ray diffractometers (XRD) can be quickly set with a variety of accessories, with superior analytic capabilities. X ray diffractometer is widely used for analyzing natural and synthetic inorganic and organic material, such as clay minerals, cement building materials, environment dust, chemical products, drugs, chemical products, drugs, asbestos, rock minerals and polymer.Its designed is based on θ-θgeometrical optics, easy for sample preparation and accessory installation. Application: Identification for one or multiple phases of an unknown specimen; Quantitative analysis for known phases of combined specimen; Structure analysis for crystal; Change of crystal structure of under unusual condition; Film analysis for material surface; Structure analysis and stress analysis for metal material.

Technical Specifications:
rated output power: 3kW
tube voltage:10~60kV (1kV /step)
tube current:5~50mA (1mA /step)
tube voltage and tube current stability: ≤ 0.1‰
metal ceramic x-ray tube:2.4KW
target material: Cu, Fe, Co, Cr, Mo
focus dimension: 1x10mm, 0.4 x14mm, 2 x12mm
one way repeatability of θd or θs: ≤0.0005°
sample horizontal:θ-θ
diffraction circle semi-diameter: 225mm, or made specially from 150mm to 285mm
scanning rate: 0.0012°~50°/min
positioning speed: 1500°/min
Scanning mode: θs/θd linking action, single action,continuous,step and omg
minimal stepping angle: 0.0001°
precision of θd or θs: ≤0.001°
2θangle linearity: National standard sample (Si, Al2o3), with the range of full spectrum, all peak angle error is not within ±0.02°
Detector: Positive proportion or shinning (SC), silicon drifting detector (SDD), high speed one-dimensional semiconductor array detector
counting method: Differential or integral, automatic PHA,fixed time correction
energy resolution: ≤25% (PC, one-dimentional array), ≤50%(SC), ≤200ev(SDD)
maximum linear counting rate: 5×105CPS, 15×104CPS,9×107CPS
system measure stability: ≤0.01%
outer dimension: 1000×800×600mm


Company Contact:


  • Phone: +864152812775

  • Address: NO 31-17 Central Street,New City Zone,Dandong City 118009,Ch, Dandong, Liaoning, China

  • Email: Email


Published date: April 28, 2017 - Modified date: April 28, 2017

  • Business Description: RST mainly produce various kinds of x ray machines. RST successfully developed the first industrial X-ray flaw detection apparatus in 1964.With unremitting efforts of several generations of our staffs, we have become national top-10 high-tech industrial manufacturers as well as being an enterprise having passed the ISO9001 international quality management system certification.

Related listings



  • Glutomatic System To Test Gluten Quality And Qantity
    Glutomatic System To Test Gluten Quality And Qantity
    Measuring and observing and testing instruments - Anyang Seven Continents International Engineering and Trading Co., Ltd - China - July 8, 2018 - 3000.00 Dollar US$

    The Glutomatic System consists of Gluten Washer JJJM54S, Gluten Index Centrifuge JLZM and Gluten Dryer JHGM. It is used for testing gluten quantity and quality of flour. Features - Easy operation - Rapid analysis - High accuracy - High degree of auto...

  • Falling Number To Detect Sprout Damage
    Falling Number To Detect Sprout Damage
    Measuring and observing and testing instruments - Anyang Seven Continents International Engineering and Trading Co., Ltd - China - July 8, 2018 - 3000.00 Dollar US$

    Falling Number is a professional instrument to detect sprout damage through testing the alpha-amylase enzyme activity in grains and flour because alpha-amylase activity is crucial index for final product quality of bread, pasta, noodles and malt. It ...

  • Testing Equipment Wireless Storage Battery Inspector
    Testing Equipment Wireless Storage Battery Inspector
    Measuring and observing and testing instruments - SiChuan Falad Electronic Technology Co., Ltd. - China - June 27, 2018 - 2000.00 Dollar US$

    Outline It is important to measure the individual cell voltages. This has to be made a couple of times during the test. It is most important to measure the cells at the end of the discharge test in order to find the weak cells. It is also very import...



Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams to avoid: Internet Crime Complaint Center - International Financial Scams
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"